CANdoISO Module (P/N NET50006)
CANdoISO Module is a compact isolated USB to CAN module, designed for embedding into OEM equipment.
The module is electrically equivalent to the CANdoISO Interface, but in an SMT (Surface Mount Technology) style PCB format.
The module may be treated as an SMT style component & soldered directly onto a larger PCB, or wired as a standalone part using the plated though holes shown in the picture below.
The CANdoISO Module is designed for customisation, for mounting in a custom enclosure or inclusion in other equipment.
Custom applications maybe written for the module using the CANdo SDK as a starting point. A consultancy service is offered to assist in the integration of the module into custom applications.
Please use the 'Support' page to request further details if this service is of interest.
CANdoISO Module Outline Specification
- Fully compliant with the CAN 2.0A & CAN 2.0B Bosch specifications
- ISO 11898-2 (High speed CAN) physical interface
- 500V galvanic isolation barrier
- Rugged CAN transceiver capable of withstanding 40V between CAN bus lines & ground
- Compact size - 40mm x 30mm x 6mm
- Multiple mounting & connection options
- CAN baud rate adjustable from 12.5k to 1M baud
- Recognises CAN data, remote & error frames
- All CAN frames timestamped
- 25.6us resolution
- 20ms + 100ppm accuracy
- Reports CAN bus status & internal status
- Calculates average CAN bus load every second
- 3 modes of CAN bus operation - normal, listen only & loopback
- Supports low level CAN message filtering
- Fully compatible with higher level protocols such as J1939, DeviceNet & CANopen
- USB v1.1, 2.0 & 3.0 compatible
- Powered via the USB port
- 100mA max. in normal mode
- 500uA max. in suspend mode
- Internal firmware upgradeable from PC over USB
- Complies with the requirements of the EU Directive 2014/30/EU on EMC
- RoHS compliant
- FREE CANdo Application software
- FREE CANdo SDK
CANdoISO Module Block Diagram
Click on the link below to download the CANdoISO Module datasheet.
CANdoISO Module Datasheet
Notes :
- The CANdoISO Module contains no internal CAN bus termination
- The CAN bus must be terminated at either end with a 120 Ohm resistor, although a single 120ohm resistor will suffice for short cable lengths (< 2m)
- For long CAN networks (>10m) & in noisy environments the use of screened, twisted pair wire is recommended
- The CAN bus ground is electrically isolated from the USB ground
- Windows CE drivers are available on request
LATEST SOFTWARE VERSION |
HARDWARE |
SOFTWARE |
RELEASED |
v1.0 |
v3.3 |
14/05/20 |
Note : All product versions are fully backwardly compatible.
If you would like to update your device with the latest software, please send a request via the 'Support' page.
|
|
|